Guide · GxP
GxP temperature monitoring: what a system needs for freezers and cold rooms.
A thermometer tells you the temperature. A GxP monitoring system tells you, and proves later, that every unit stayed in range and that every alarm was acted on.

A thermometer tells you the temperature. A GxP monitoring system tells you, and proves later, that every unit stayed in range and that every alarm was acted on.
A GxP temperature monitoring system records the temperature of freezers, refrigerators, cold rooms and storage areas continuously, alarms when a limit is crossed, and keeps records that a regulated organisation can show to an inspector as evidence.
| Part | What it must do |
|---|---|
| Sensors | Read each unit and, where needed, product probes and door contacts |
| Alarm engine | High, low, rate of change, communication loss and sensor failure |
| Escalation | Reach someone who acts, at any hour, until acknowledged |
| Excursion record | Duration, peak, cause and disposition for every event |
| Calibration | Due dates tracked so no sensor runs out of calibration |
| Audit trail | Readings, alarms and actions kept, time-stamped and unalterable |
| Validation | Installation, operational and performance qualification |
For excursions on the road rather than in storage, read temperature excursion response in transit.
ColdWatch monitors freezers from −80 °C to cold rooms at 2–8 °C, plus product probes and door contacts, on the sensors you already have, over BACnet/IP or Modbus TCP. It raises five alarm types (high, low, rate of change, comms gap and sensor failure) and escalates by screen, email, SMS and push until someone acknowledges with a mandatory comment. AI projects drift forward to say which unit is likely to breach next and roughly when. Excursions go into a register with duration, peak, shift and severity; calibration due dates are tracked with reminders at 30, 15 and 7 days; and every reading, alarm and action is kept in an append-only ALCOA+ audit trail for five years, with IQ/OQ/PQ documents delivered as part of go-live.
A system that continuously records storage temperatures, alarms and escalates on limit breaches, and keeps validated, time-stamped records that can be shown to an inspector.
Not always. Systems that speak BACnet/IP or Modbus TCP can often read the sensors and building-management equipment already installed.
Typically installation, operational and performance qualification (IQ/OQ/PQ) against your requirement specification.
See it on your own data. ColdWatch — Every freezer, every minute. Book a 30-minute working session with an engineer.