Calculator

Mean kinetic temperature calculator for storage temperature readings.

Paste your temperature readings to get the mean kinetic temperature, the arithmetic mean and the range, worked out in your browser.

Mean kinetic temperature–
Arithmetic mean–
Minimum / maximum–
Readings used–

Runs in your browser; nothing is sent anywhere. Use equally spaced readings.

How do you calculate mean kinetic temperature?

Mean kinetic temperature (MKT) = (ΔH ÷ R) ÷ −ln[(e−ΔH/RT₁ + … + e−ΔH/RTₙ) ÷ n], with every temperature T in kelvin (°C + 273.15), R = 0.0083144 kJ/mol·K and ΔH the activation energy, for which 83.144 kJ/mol is the commonly used default. MKT weights warm readings more heavily than the plain average, so it is always at or above the arithmetic mean. Use equally spaced readings, and follow your QA procedure for the activation energy and the period assessed. A GxP temperature monitoring system that records every reading on a time-stamped, append-only audit trail gives you the readings to paste here. Read how to investigate an excursion.

By hand or in a spreadsheet, the same formula runs in five steps:

  1. Convert each reading to kelvin: T = °C + 273.15.
  2. For each reading, work out e−ΔH/RT. With ΔH = 83.144 kJ/mol and R = 0.0083144 kJ/mol·K, ΔH ÷ R is exactly 10,000 K, so this is e−10,000/T.
  3. Average those values across all n readings.
  4. Take the natural log of the average and change its sign.
  5. Divide 10,000 K by that number and subtract 273.15 to get MKT in °C.

Worked example: one warm reading in a 2–8 °C fridge

Illustrative readings. Eight equally spaced readings from a fridge: seven at 5 °C and one at 15 °C, for example while a door was left open.

MeasureResult
Arithmetic mean(7 × 5 + 15) ÷ 8 = 6.25 °C
e−10,000/T at 5 °C (278.15 K)2.4 × 10−16
e−10,000/T at 15 °C (288.15 K)8.5 × 10−16, about 3.5 times larger
Mean kinetic temperature7.11 °C

One reading out of eight was warm, yet MKT sits 0.86 °C above the plain average, because the exponential gives the warm reading about 3.5 times the weight of each cold one. That is the point of MKT: it reflects the extra degradation a product suffers in warm periods, which a simple average hides. The default readings in the calculator above give a mean of 25.46 °C and an MKT of 25.51 °C, because they vary much less.

Questions

What is mean kinetic temperature?

A single temperature that expresses the combined thermal effect of fluctuating storage temperatures, weighting warm periods more heavily than a simple average.

What activation energy is used for MKT?

83.144 kJ/mol is the commonly used default; your QA procedure may specify a different value for a product.

What is the formula for mean kinetic temperature?

MKT = (ΔH ÷ R) ÷ −ln[(e^(−ΔH/RT₁) + … + e^(−ΔH/RTₙ)) ÷ n], with each temperature in kelvin, R = 0.0083144 kJ/mol·K and ΔH usually 83.144 kJ/mol, so ΔH ÷ R is 10,000 K. It is known as the Haynes equation and gives the result in kelvin; subtract 273.15 for °C.

Why is MKT higher than the average temperature?

Because degradation speeds up exponentially with temperature, the formula gives warm readings more weight than cold ones. MKT therefore equals the arithmetic mean only when every reading is the same, and is higher whenever readings vary. The more the temperature swings, the bigger the gap.

See it on your own data. ColdWatch — Every freezer, every minute. Book a 30-minute working session with an engineer.

General guidance, current as of the date above. Figures and examples are illustrative unless a source is linked.