
Glossary · Cold chain & pharma
What is Controlled room temperature (CRT)?
Controlled room temperature is a defined storage limit for medicines that do not need a fridge. See label wording, India's 30 °C/75% RH zone and how MKT fits.

Controlled room temperature is a defined storage limit for medicines that do not need a fridge. See label wording, India's 30 °C/75% RH zone and how MKT fits.
In pharma, "room temperature" is not whatever the room happens to be. The WHO stability guideline (TRS 1010, Annex 10, 2018) says terms such as "ambient conditions" or "room temperature" should be avoided on labels. It recommends a statement tied to the stability data instead: "Do not store above 25 °C" or "Do not store above 30 °C", with "Store in a refrigerator (2 °C to 8 °C)" for cold products. Controlled room temperature is the everyday name for that non-refrigerated, limit-bound storage.
Most stores keep CRT shelves next to cold rooms and freezers. A GxP temperature monitoring system such as ColdWatch covers freezers from −80 °C to cold rooms at 2–8 °C, with alarms that escalate by screen, email, SMS and push until acknowledged. For the cold side, see what temperature a pharma cold room should be.
WHO's annex compares storage statements used in different regions. Its examples include "Store at 15 °C to 30 °C" (USA, Canada), "Store at 25 °C; excursions permitted to 15 °C to 30 °C" (USA), and "Store at controlled room temperature (15–30 °C)" (Canada). For products approved on 25 °C/60% RH data and sent to hot zone IV countries, WHO recommends the statement "Do not store above 25 °C".
| Label says | What the store must do |
|---|---|
| Do not store above 25 °C | Keep the shelf at or below 25 °C all year |
| Do not store above 30 °C | Keep the shelf at or below 30 °C all year |
| Store between 15 and 30 °C | Hold a band, so cold winters matter too |
| Store in a refrigerator (2 °C to 8 °C) | Not CRT; this belongs in a cold room or fridge |
WHO splits the world into climatic zones for stability testing. Its annex defines zone II as 25 °C/60% RH, zone IVa as 30 °C/65% RH and zone IVb as 30 °C/75% RH. India's New Drugs and Clinical Trials Rules, 2019 set long-term stability testing for new drugs intended to be stored under general conditions at 30 °C ± 2 °C / 75% RH ± 5% RH, the zone IVb condition. A product labelled "Do not store above 25 °C" sits below that condition, so in an Indian summer it needs a cooled store, not just a roof.
An excursion is a period outside the labelled limit. Mean kinetic temperature (MKT) is one figure that expresses the combined heat stress of a period, weighting hot spells more than a simple average does. QA teams use it to judge whether a short excursion changed the overall exposure.
Illustrative only. A CRT room labelled "do not store above 25 °C" reads 24 °C for six days and 34 °C for one day after a power cut. The arithmetic mean is (6 × 24 + 34) ÷ 7 = 25.4 °C. With an activation energy of 83.144 kJ/mol, the MKT works out to about 26.2 °C, higher than the average because the hot day counts for more. You can check figures like these in our MKT calculator; the decision on the stock still rests with QA and the product's stability data.
Where this shows up in our work. ColdWatch: Freezers and cold rooms monitored live, escalating alarms, AI breach prediction and an ALCOA+ audit trail. Book a 30-minute working session with an engineer.
Controlled room temperature is storage for medicines that do not need refrigeration, held within a limit stated on the label, such as "Do not store above 25 °C" or "Do not store above 30 °C". The limit has to be kept in every season, not only on mild days.
No. WHO's stability guideline says terms such as "room temperature" should be avoided on labels; controlled room temperature means a defined, monitored limit backed by stability data.
India's New Drugs and Clinical Trials Rules, 2019 set long-term stability testing for new drugs stored under general conditions at 30 °C ± 2 °C / 75% RH ± 5% RH, which WHO defines as climatic zone IVb.